Configurator 5.0

 

Up
Configurator 4.0

The current version of Configurator is Version 5.0.  It was released in April 2004.  For those who may still be using the very obsolete Version 3.0, first click on the Configurator 4.0 button on the left to display a summary of the new features added at Version 4.0.  Then, return here and review the summary of features added with Version 5.0.

Why You Should Update to Configurator 5.0

Key features and improvements of this new release of Cornerstone Configurator are:

bullet

User Requested Features – These include operational and performance improvements, expanded transaction security and audit tracking, enhanced display and presentation features, and easier to use input and selection actions.  These are described in more detail below.

bullet

Latest HART® Specifications - Updated to the very latest HART standard parameter tables published periodically by the HART Communication Foundation.

bullet

Support for Many Smart Instruments - Optional Model Support libraries provide comprehensive HART configuration and calibration support for a wide variety of instruments from ABB, Honeywell, Rosemount, Yokogawa and many other manufacturers.  Use one Cornerstone Configurator program to manage ALL of your HART instruments, regardless of the manufacturer.  Many new and updated ModLibs have been added since the introduction of version 4.0.

It is very important that all current Configurator users purchase the update to this latest version to:

bullet

Access New Features - Take advantage of new and improved features to reduce your maintenance costs, improve regulatory compliance, and improve product quality.

bullet

Access New HART Instruments - New or revised ModLibs to support new and updated HART instrument models are only built for the latest version of Configurator.  You must update to the latest release to gain access to these new capabilities.

bullet

Insure Compatibility with New Windows® - Only the latest release is tested for installation and operation on new PC hardware and Windows operating system software, including Windows 2000 and Windows XP.

bullet

Repair Problems - The new release incorporates the entire collection of problem fixes and other internal improvements implemented since the release of the previous version.

bullet

Continue Access to Technical SupportTo provide the most responsive customer service, it is not practical for a software developer to maintain support capability for outdated versions of products.  Technical support, including consultation concerning application questions, troubleshooting, and problem resolutions, is only available for the current version established by this new release.

What's New in Configurator 5.0

This Summary describes the most notable new features and significant improvements to existing functions that were added in moving forward from the previous version 4.0 to the current version 5.0 of Cornerstone Configurator.  The improvements are numerous and have been introduced throughout all areas.  For purposes of review they are grouped into the following functional topics.

bullet

Operational and performance improvements

bullet

Expanded transaction security and audit tracking

bullet

Enhanced display and presentation features

bullet

Easier to use input and selection actions

bullet

New libraries to interface HART instruments and multiplexer systems

bullet

Database updates

NOTICE - If you are a current user of Cornerstone Base Station,  you should receive before May 1, 2004, an official notice from us with information about updating your software to version 5.0.  If you have not received your notice by that date, please click on the link below to contact us about your update.

Update Inquiry Form

Operational and Performance Improvements

CD ROM Media - A primary objective for Version 5.0 is the delivery of Configurator on CD ROM.  To achieve Version 5.0, the entire installation program and packaging was re-implemented to work from CD.

Windows 2000 and Windows XP - Version 5.0 is the first version to fully support installation and operation on Windows 2000 and Windows XP.  Version 5.0 is required for ongoing support in either of these environments.

HdataLink2 ComLib – This advanced ComLib is now installed as the default HART modem ComLib for Configurator.  Version 5.0 is the first release to include this improved, higher performance HART modem interface as an integral part of the installation package.  The HdataLink2 ComLib is required for operation on Windows NT, Windows 2000 or Windows XP.

Updated Authorization Software - Version 5.0 utilizes the latest release of the authorization software which is necessary for best operation on Windows NT, Windows 2000 or Windows XP.

Latest HART Tables - During the installation, the Vendor, Model and Units tables are updated to the latest tables released by the HCF.

Expanded Transaction Security and Audit Tracking

In response to customer requests and following the consensus of audit guidelines, Version 5.0 contains improved security and transaction tracking features.  The basic objective of these modifications is to better protect against unauthorized access and changes and to better document the change process.

Sign On Security

The Sign On function was changed so that a user is only allowed three consecutive attempts to sign on the Cornerstone Station.  Each unsuccessful attempt is logged to the Event Log.  If the user attempting to sign on is not a System Manager or if the user attempting to sign on is a System Manager and there are at least 2 System Managers in the user database, after three consecutive unsuccessful attempts to log on, the user name is deleted from the User database and a Deleted User event is logged in the Main Event Log.  To facilitate this change, the User Name was changed from an edit field to a drop down list, which allows only the selection of user names in the list.

Change Security

The same approach employed for Sign On security has been extended to the approval of selected changes.  When a change to one of the covered parameters or functions is attempted, the user is requested to verify his password before the change will be made.  The Verify Password dialog allows the user up to three attempts to enter the correct password.  Each incorrect attempt is logged to the Main Event Log.

The actions covered by this new level of change security are listed below.  Additional comments are provided where necessary to fully describe the actions for a particular function.

bullet

Setup Event Log

bullet

Instrument Delete

bullet

Setup On-line Event Log

bullet

Setup Users - If a user other than “STW” attempts to add, delete, or modify a user, the Verify Password dialog is raised which requests that the user supply his password in order for the change to be made.

Enhanced Display and Presentation Features

These enhancements are found throughout Version 5.0.  The list includes expanded fields, more powerful tree controls, improved list presentation and column arrangement, 3D effects, the more widespread inclusion of device type abbreviations and category icons, and a general review for standardization and consistency in the user interface.

The Database Select Instrument From List Function dialog was enlarged and the Selection Criteria display area was reduced to show more instruments in the instrument list.

A Print button was added to the Select Instrument From List dialog to allow printing a report of all the instruments currently listed in the instrument list.  The report prints two lines for each instrument in the list, showing the information in the list columns.

The labels in the instrument summary are now right justified instead of left justified to match label fields in dialog boxes.

In previous versions, Group codes, Vendor Codes, Model Codes, and others were stored as part of the item text in list boxes or combo boxes when these names were listed.  This practice determined the width of the list or combo boxes and resulted in names being truncated because the control was not wide enough to show all the characters of the name.  In Version 5.0 the widths of many of the controls which display Groups, Vendors, etc. have been expanded to show the complete name.

The maximum number of rows that can be displayed in the Communication Manager window was increased to accommodate higher resolution display settings.

In the HART Comm window, two additional lines in the instrument summary group area are reserved for use by the connected instrument for the display of instrument specific information.   

Improved monitoring dialogs support an even wider variety of HART devices by allowing unit strings to be displayed in the Monitor Numerical dialog whose codes do not conform to the standard HART table for units. 

In the Print Selected Instruments Function, an Ignore Case check box was added to the Print Selected Instruments dialog to allow, when checked, the current sort column of the instrument list to be sorted via a case insensitive sort. 

3D effects were added to the instrument list in the Connect Instrument From List dialog.

The Max Number of Event Log Entries increment is now fixed at 100 instead of varying with the hard disk geometry and file system installed.  The number of entries can be varied from 100 to 25,000 in 100 increments.

Easier to Use Input and Selection Actions

As noted above in the discussion of enhanced display features, improved tree controls have been implemented.  These controls not only enhance the presentation; they also add flexibility and capability to the instrument selection process, as well as being more consistent across all Configurator functions.  The instrument list in the Multiple Instruments Function dialog was changed to use the latest tree control to allow the display of the same instrument information as the Select Instrument From List dialog.

A View push button was added to the Select Instrument From List dialog to allow the viewing of the instrument parameters via the View Instrument dialog for the currently selected instrument in the instrument list.  This is a fast, easy way to check the details for an instrument without having to enter the Edit function.  This is tremendously useful for a quick review of parameters or for confirming the instrument to be selected from several that are almost identical.

The Tag and ID controls in the Select Instrument dialog and in the Connect Instrument on Network are now drop down lists which show up to the last 100 Tags or IDs that were entered previously in the dialog to make it easy to pick a recently selected device.

Controls for entering the time of day were added to the Edit Instrument Dates dialog to allow the entry of the time when editing the instrument dates. A control for entering the time of day for the Last Calibration Date was added to the Instrument Replicate Function dialog.

The labels in the instrument summary group are now right justified instead of left justified to match label fields in dialog boxes.

In the Instrument Add Function, the vendor list now only shows those vendors which have models defined.  This reduces the potential for wasted effort and errors.  A control was added for entering the time of day for the Last Calibration Date.

An Ignore Case check box was added in several dialogs where the user selects one or more instruments (e.g., the Select Instrument From List dialog).  When checked, the current sort column of the instrument list is to be sorted via a case insensitive sort.  Previously, all column sorts were case sensitive.

New Libraries

New versions of all optional components for Base Station, Field Station and Configurator were released with Version 5.0 of all three of these products.  There are new libraries, updated libraries to support newer instrument revisions, and some new features in existing libraries.  Previous 4.x or earlier versions of these components will not work with Configurator 5.0.

This section lists only the ModLibs and ComLibs that are new, or that have been significantly updated, since the previous version of Configurator (4.0).  Complete listings of all currently available libraries are presented in other pages on our website.  You can use the hyperlinks shown in the text below to access those pages.

New ModLibs

A number of new optional ModLibs have been made available.  Several ModLibs have been updated to support new instrument versions.  Only the ModLibs that are new or have been updated since the previous Configurator release (version 4.0) are listed below.  For a complete list of the currently available interface libraries, please access our Model Libraries page.

ABB Automation ModLib Package

bullet

Hartmann & Braun TH02 (new ModLib)

bullet

Hartmann & Braun TZID-C (new ModLib)

Flowserve ModLib Package  (new Package)

bullet

Logix 520 (new ModLib)

bullet

Logix 1200 (new ModLib)

Honeywell ModLib Package

bullet

Honeywell STT25T (new ModLib)

Metso Automation ModLib Package  (new Package)

bullet

ND820 (new ModLib)

bullet

ND820T (new ModLib)

ModLib Collection Package

bullet

Kayray/Sensall 3680 (updated ModLib)

Moore Industries ModLib Package (new Package)

bulletTHZ/TDZ
bulletTRZ

Rosemount ModLib Package

bullet

Rosemount 3051C (ModLib for new instrument rev.)

bullet

Rosemount 8800 (ModLib for new instrument rev.)

bullet

Kayray/Sensall 3680 (updated ModLib)

Tyco ModLib Package  (new Package)

bullet

Tyco SmartCal Positioner (new ModLib)

Westlock Controls ModLib Package

bullet

ICoT 5000 Positioner (new ModLib)

WIKA ModLib Package  (new Package)

bullet

T32 (new ModLib)

bullet

UniTrans IUT-10 & IUT-11 (new ModLib)

New ComLibs

MTL 8000

A new ComLib has been released for the new MTL 8000 product line.  Support for this new product as well as the existing MTL 4840 are now included in this ComLib package.

For a complete list of the currently available Communication interface libraries, please access our Comm Libraries page.

Database File Names

Some Cornerstone database file names include a number that indicates the revision of the database schema.  Since the schema has not changed with this release, those file names have not changed.  If you have built database save and restore scripts according to the recommendations in the section, then you should not have to make any changes to them.

Update of Previous Version Database During Installation

This new version of the software includes some changes and additions to the Cornerstone Instrument Database files.  Therefore, a conversion of your existing databases is a necessary part of installing the new version of the software.  The new install process included with this version automatically performs the necessary modifications to your existing version 3.0.11 or 4.0 database to make it compatible with the new 5.0 release of the software.

After an installation of the 5.0 software over a 3.0.11 or 4.0 system, you must make sure not to attempt a restore of a 4.0, or older database backup onto your 5.0 system.  It is a good idea to make a backup of your database both before and after your 5.0 installation.  The “before” backup is of your 3.0.11 or 4.0 database.  This could be needed in case of some problem with the installation of the 5.0 software affecting your existing database.  The “after” backup is your first 5.0 compatible backup, to help you recover from future problems (hard disk crashes, etc.).

This may be a good place to remind our users that it is very important to adopt a rigorous procedure for the periodic backup of your Cornerstone database files.  You may need these to recover from some future hardware or system problem that damages your database files.

 

Home Up Site Guide Contact Us

applied system technologies, inc.
p.o. box 309
dunnellon, florida,  U.S.A.  3
4430

ă Copyright 2000-2005 Applied System Technologies, Inc.   All rights reserved.
Cornerstone and the Cornerstone logo are trademarks of Applied System Technologies, Inc. 
Specifications subject to change without notice.

This site was last updated on 17 May 2005.